Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T04PL01629
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2005 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* 1) TURNED IN PIMA COUNTY DEPT. OF ENVIORMENTAL QUALITY APPROVAL OF CONSTRUCTION (SEWER) |
|
| 09/28/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :*/MANHOLE #1 VACUUM TEST OK. | |
| 09/22/2004 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999*/MANHOLE #1 FAILED VACUUM TEST |
|
| 09/21/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* MANHOLE # 3 TO MANHOLE # 4 INCLUDING 4" LATERAL THRU HCS INTO BUILDING FOR FUTURE ? INTO 9356 RITA RD 5 PSI AIR TEST OK MANHOLE # 2 VACUUM TEST OK MANHOLE # 3 VACUUM TEST OK MANHOLE #4 VACUUM TEST OK MANHOLE # 5 VACUUM TEST OK 1) MANHOLE #1 VACUUM TEST AT LATER DATE. |
|
| 09/20/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :*/ 1) MANHOLE #3 TO MANHOLE #5 INCLUDING 2) 4" LATERALS THRU HCS CONNECTION, THRU 2-WAY CLEANOUTS INTO BLDG FOR FUTURE 5 PSI AIR TEST OK 2) MANHOLE #3 TO MANHOLE #4 INCLUDING (1) 4" LATERAL THRU HCS CONNECTION, THRU 2-WAY CLEANOUT 5' INTO BLDG FOR FUTURE 5 PSI AIR TEST (WILL NOT HOLD TEST). MANHOLE #4 4" SEWER TO HCS THRU 2-WAY CLEANOUT 5' INTO BLDG FOR FUTURE 5 PSI AIR TEST OK | |
| 09/16/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* 4" DUCTILE IRON INSTALLED PER PC/COT DETAIL WWM-108 IN (4) LOCATIONS PER PLAN. 1) NEED AIR TEST ON PIPING INCLUDING HCS CONNECTION FROM MANHOLE #3 TO #4, MANHOLE #4 THRU HCS CONNECTION AT 9356 E. RITA RD, FROM MANHOLE #3 TO MANHOLE #5 INCLUDING ( 2) HCS CONNECTIONS TO 9348 E. RITA RD. 2) NEED VERIFICATION OF GRADE ON ENTIRE SEWER. 3) NEED PIMA COUNTY CERTIFICATE OF CONFORMANCE FOR SEWER. 4) NEED VACUUM TEST ON MANHOLES. 5) NEED LETTER FROM ENGINEER STATING CORRECT CROSSING OF SEWER & WATER ON WEST SIDE OF PROJECT. |