Permit: T04PL01600

Parcel: 14025106B

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/13/2004 PLUMBING - FINAL Approved IVRS - Inspection :*GAS PRESSURE TEST IS OK]
WATER HTR FLU VENT IS OK OWNER WILL CHANGE T& P DRAIN TO APPROVED MATERIAL.
09/08/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL PROVIDE (3)? SHEET METAL SCREWS PER JOINT FOR WATER HTR FLU VENT AND @ APPLIANCE COLLAR
2)SHALL LOCATE GAS SHUT OFF VALVE FOR WALL FURANCE PRECEEDING FLEX CONNECTOR
3)RE TEST SYSTEM
4)SHALL PROVIDE WATER HTR ENCLOSURE @ TIME OF INSPECTION
5)SHALL EXTEND T&P DRAIN AND TERMINATE 6" ABOVE GRADE