Permit: T04PL01580

Parcel: 118040820

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/28/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/1)GAS PRESSURE TEST IS OK 2)GAS SHUT OFF VALVES OK 3)WATER HTR FLU VENT T&P VALVE & DRAIN IS OK 4)OK TO BACKFILL TRENCH
09/08/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL PROVIDE AIR PRESSURE TEST ON SYSTEM MIN. 10 LBS @ TIME OF INSPECTION
2)SHALL PROVIDE AGA OR CSA GAS SHUT OFF VALVES FOR APPLIANCES
3)SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT FOR WATER HTR FLU VENT AND @ APPLIANCE COLLAR
4)SHALL EXTEND T&P DRAIN TO DAYLIGHT TERMINATE MIN. 6" ABOVE GRADE. COPPER, CPVC OR GALV. MATERIAL