Permit: T04PL01522

Parcel: 130151370


Addresses:

4518 E 25TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/10/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/08/2004 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*/12 PSI AIR TEST FROM METER TO WATER HEATER AND FURNACE OK 1)SEE NOTES #2 & #4 WATER HEATER TEMPURATURE PRESSURE RELIEF REQUIRES GRAVITY DRAIN TO EXTERIOR OF STRUCTURE
08/25/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/DENIED
1) MINIMUM 10 PSI TEST ON GAS SYSTEM AT TIME OF INSPECTION
2)PROVIDE BONDING OF BUILDING GAS PIPING
3) WATER HEATER REQUIRES UPPER & LOWER COMBUSTION AIR TO CLOSET
4) WATER HEATER TEMPERATURE & PRESSURE RELILEF REQUIRES GRAVITY DRAIN TO DAYLIGHT OR CITY SIGNED PETITION OF APPREAL ON SITE WITH CORRECT INSTALLICATION
5) VENT FROM WATER HEATER & FURANCE WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE TOP OF COOLER
6) WHERE UNIONS ARE NECESSARY LEFT & RIGHT NIPPLE COUPLINGS SHALL BE USED