Permit: T04PL01512

Parcel: 117083730


Addresses:

946 S 7TH AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/06/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*/
10/05/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT AND @ APPLIANCE COLLAR 2)SHALL TRIM TREE AROUND FLU VENT
09/20/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GATES WERE LOCKED
08/26/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/DENIED
1)P.E. GAS LINE REQUIRES 18" OF COVER. GAS LINE NOT DEEP ENOUGH
2)AIR PRESSURE TEST REQUIRED FOR ENTIRE SYSTEM 10 LBS MIN.
3) WATER HTR ENCLOSURE REQUIRES 2-10X10 LOURER? GRILLS LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR
4) NOTE: WATER HTR ENCLOUSURE WAS LOCKED! THERE COULD BE MORE CODE VIOLATIONS. PLEASE HAVE PLBS. CONTRACTOR CHECK WATER HTR. CHECK FLU VENT & CAP
5) CAN NOT HAVE FLEX CONNECTOR PENETRATE WATER HTR ENCLOSURE
08/23/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GATES LOCKED NO ONE HOME