Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04PL01509
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/23/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*/APPROVED 1) CORRECTIONS MADE WITH ONE EXCEPTION: DRAIN FOR HAND SINK NOT APPROVED. REVIEWED CORRECTIONS W/CONTRACTOR. INSPECTOR WILL STOP BACK BY TO VERIFY COMPLIANCE 2)PLUMBING FINAL OK 3)OK FOR C OF O PENDING ANY OTHER INSPECTION |
|
| 08/20/2004 | PLUMBING - FINAL | Not ready for Inspection | 1) PLAN APPROVED BY RWS ON 8/18/04 APPROVED IN ERROR-HAND SINK MAY NOT BE INDIRECTLY WASTED, BUT MUST BE DIRECTLY CONNECTED TO SANITARY SEWER 2) INDIRECT WASTE PIPING GREATER THAN FIVE FEET TO BE DIRECTLY TRAPPED 3) INDIRECT WASTE PIPING MAY NOT BE COMBINED 4) NONE OF THE PLUMBING DESCRIBED ON P-1 HAS BEEN INSPECTED OR APPROVED, AND P-2 FLOOR SINK WAS NOT EXISTING, BUT WAS INSTALLED AND COVERED WITHOUT INSPECTION 5) NO EXPANSION TANK ON WATER HEATER T & P RELIEF DRAIN TO BE HARD PIPE GRAWIKY DRAIN |