Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 09/23/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)GAS SYSTEM SHALL HAVE 10 PSI MINIMUM AT TIME OF INSPECTION. 2)WATER HEATER T&P DRAIN TO GRAVITY DRAIN TO DAYLIGHT. VENT TO BE INSTALLED CORRECTLY. 3)PLEASE PROVIDE ROOF ACCESS AT NEXT INSPECTION. 4)PROVIDE BONDING OF BUILDING GAS PIPING. |
|
| 09/10/2004 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :*/ 1) THERE IS AN ADDRESSING PROBLEM THAT NEEDS TO BE CORRECTED | |
| 09/02/2004 | PLUMBING - GAS PRESSURE TEST | Cancelled | PER CHRIS 721-2071 | |
| 09/02/2004 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 08/23/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/DENIED-PROVIDE CORRECT ADDRESS ON PERMIT, WITH ACCESS TO BUILDING AT TIME OF INSPECTION |