Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/07/2005 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK FOR UNDERGROUND GAS LINE ONLY. 2) OK TO BACKFILL TRENCH | |
| 11/29/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SHALL PROVIDE AIR PRESSURE TEST ON ENTIRE SYSTEM 2) SHALL PROVIDE MINIMUM 18 GAUGE TRACER WIRE ON UNDERGROUND GAS LINE 3) REMOVE UNION IN LINE BY GAS METER 4) SHALL PROVIDE AGA OR CSA SHUT OFF VALVE AT WATER HEATER 5) T & P DRAIN SHALL TERMINATE TO DAYLIGHT 6) REPLACE ASBESTOS FLU VENT WITH B-VENT AT WATER HTR AND PROVIDE (3) SHEET METAL SCREWS PER JOINT |