Permit: T04PL01499

Parcel: 128151220


Addresses:

848 S CHARLES AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
09/21/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
09/15/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
SEE NOTE 1 FROM 09/8/04 INSPECTION
09/08/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/1) 10 PSI AIR TEST SHALL BE ON ENTIRE SYSTEM AT TIME OF INSPECTION AND HOLD WITH NO PRESSURE DROP FOR 15 MINUTES
2) USE EITHER COPPER OR STEEL PIPING FOR T&P DRAINS OR PROVIDE DIGCOCTRIC? UNIONS FOR TRANSITION.
08/31/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES & COUPLINGS SHALL BE USED (2) ON ROOF (2) AT MOTOR
2)ENTIRE GAS SYSTEM SHALL BE 10PSI TEST AT TIME OF INSPECTIONS
3)RIGID PIPE WATER HEATER T&P DRAIN GRAVITY DRAIN T DAYLIGHT-NO FLEXS
08/23/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/NOT READY
1) 10 PSI MINIMUM PROSSURE TEST OUTING GAS AT TIME OF INSPECTION
2)WITONG? UNIONS ARE NECESSARY RIGHT-LEFT NIPPLES & COUPLINGS SHALL BE USED
3) PROVIDE BONDING OF BUILDING GAS PIPING
4) PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES
5) WATER HEATERS TEMPURATURE & PRESSURE RELIEF DRAINS TO GRAVITY DRAIN TO DAYLIGHT AND STORMWATER AT 90 DEGREES DOWN 6" TO 24" FROM FINISH GRADE WITH APPROVED PIPING MATERIALS.
6) SECURE ALL PIPING WITH APPROVED CLAMPS AND AT 8' INTERVALS.
7) PROVIDE LOWER COMBUSTION AIR FOR WATER HEATER.