Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04PL01495

Parcel: 130053370


Addresses:

2209 S PLUMER AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/20/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/APPROVED-CORRECTION MADE-GAS CVARD AT METER 889-1888
08/19/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/NOT READY 1)PROVIDE PROPER BONDING OF BLD GAS PIPING 2)PROVIDE DBL WALL VENT THRU ROOF WITH APPROVED CAP 3)PROVIDE UPPER COMBUSTION AIR FOR WATER HEATER
03050-20SPI AIR TEST FROM METER LOCATION TO ROOF TOP UNIT, STOVE, WATER HEATER & DDRYER (APPROVED)
PETITION OF APPROVAL FOR TEP ON SITE.