Permit: T04PL01476

Parcel: 13625010A


Addresses:

6601 E 38TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/26/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/APPROVED
25 PSI AIR TEST FROM METER 1" SCOTCH COAT UNDER GROUND TO EXISTING BLD. SERVICE EXTENDING TO WATER HEATER, STOVE AND FURANCE
GAS CARD AT METER
08/24/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/DENIED-
1) REMOVE THREAD PROTOCTOR AT STOVE AND USE APPROVED CUPLING
2) WATER HEATER T&P DRAIN TO 90 DEGREE DOWN AT TERMINATION AND HAVE UN THREADED INSP
3) HAVE WATER HEATER APPLIED TO YOUR PERMIT
4) PLEASE PROVIDE 0-15 PSI PRESSURE TEST GAUGE AND RETEST SYSTEM
5) VENT FROM WATER HEATER TO BE 3' ABOVE TOP OF COOLER WHEN WITHIN 10' OF COOLER INTAKE AND SECURED PROPENCY
6) PROVIDE LOWER COMBUSTION AIR FOR WATER HEATER CLOSET.