Permit: T04PL01441

Parcel: 118033820

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04PL01441

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/22/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/1)GAS PRESSURE TEST IS OK 2)ALL CORRECTIONS HAVE BEEN MADE.
09/10/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/03/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL REMOVE ALL UNIONS IN GAS LINE AND PROVIDE A RIGHT & LEFT HAND NIPPLE.
2)SHALL PROVIDE GAS SHUT OFF VALVE FOR RANGE AND IF GAS RANGE NOT AVAILABLE @TIME OF INSPECTION THEN PLUG OFF GAS VALVE
3)CAN NOT HAVE FLEX CONNECTOR PENETRATE THE APPLIANCE HOUSING FOR FURANCE
4)CAN NOT HAVE A FLEX LINE IN T&P DRAIN FOR WATER GTR.
5)RE TEST SYSTEM