Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04PL01441
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/22/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*/1)GAS PRESSURE TEST IS OK 2)ALL CORRECTIONS HAVE BEEN MADE. | |
09/10/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
09/03/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL REMOVE ALL UNIONS IN GAS LINE AND PROVIDE A RIGHT & LEFT HAND NIPPLE. 2)SHALL PROVIDE GAS SHUT OFF VALVE FOR RANGE AND IF GAS RANGE NOT AVAILABLE @TIME OF INSPECTION THEN PLUG OFF GAS VALVE 3)CAN NOT HAVE FLEX CONNECTOR PENETRATE THE APPLIANCE HOUSING FOR FURANCE 4)CAN NOT HAVE A FLEX LINE IN T&P DRAIN FOR WATER GTR. 5)RE TEST SYSTEM |