Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04PL01435

Parcel: 125042380


Addresses:

921 N PLUMER AV

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/16/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) PLEASE PROVIDE VALVE BEFORE UNION OR PROVIDE RIGHT LEFT NIPPLE AT COUPLING 2) SEAL AROUND ABS 3) PROVIDE TEST ON COMPLETE SYSTEM 4) CODE VIOLATION ON REAR UNIT WATER HEATER VENT-SEE CODE FOR PROPER LENGTH 5) PROVIDE BONDING ON GAS LINE
08/16/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/TEST OK ON COMPLETE SYSTEM TO EXISTING? FIXTURE. CALL GAS CO 889-1888-CARD AT METER SET