Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 09/28/2004 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 09/21/2004 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* | |
| 08/19/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) GAS SYSTEM SHALL HOLD MINIMUM 10 PSI TEST FOR 15 MINUTES AT TIME OF INSPECTION 2) AGA OR CSA APPROVED GAS VALVES SHALL BE AT ALL APPLIANCE 3) PROVIDE BONDING OF BLDG GAS PIPING 4) VENT FROM WALL HEATER WHEN WITHIN 10' OF COOLER INTAKE TO BE 2' ABOVE TOP OF COOLER |