Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04PL01395

Parcel: 115172200


Addresses:

1532 N EL RIO DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/08/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/04/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*1)SWITCH ELBOW & TEE AT RISER. RETAPE ELBOW 2)REQUIRE 10# AIR TEST
08/06/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/ 1) PLEASE READ OVER GAS PIPE INSTALLATION STANDARDS 2) REMOVE BLACK PIPE FROM UNDERGROUND 3) PROVIDE APPROVED PIPE (GREEN PIPE) UNDERGROUND 4) PLEASE PROVIDE APPROVED PRIMER AND 10 MILL TAPE AT JOINTS-AS PER CODE