Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :*/ 1) CORRECTIONS MADE 10 PSI AIR TEST ON EXISTING PIPING UNDERGROUND TO BLDG TO WATER HEATER, DRYER, STOVE AND ROOF TOP UNIT OK 2) GAS CARD AT METER | |
| 08/03/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection :10 PSI TEST REMOVE UNION FROM GAS LINE IN WATER HEATER ENCLOSURE & USE A REVERSE THREAD COUPLING & NIPPLE PROVIDE A GAS SHUT OFF VALVE AT WATER HEATER PROVIDE HIGH & LOW COMBUSTION AIR OPENINGS IN WATER HEATER ENCLOSURE. PROVIDE A ROOF JACK AT ROOF PENETRATION GAS FLEX CANNOT PENETRATE THE CABINET OF FURNACE ON ROOF PROVIDE A DRAIN PIPE ON T&P VALVE. CAP OFF GAS PIPE TO DRYER |