Permit: T04PL01367

Parcel: 126171430

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
08/05/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*/ 1) CORRECTIONS MADE 10 PSI AIR TEST ON EXISTING PIPING UNDERGROUND TO BLDG TO WATER HEATER, DRYER, STOVE AND ROOF TOP UNIT OK 2) GAS CARD AT METER
08/03/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :10 PSI TEST
REMOVE UNION FROM GAS LINE IN WATER HEATER ENCLOSURE & USE A REVERSE THREAD COUPLING & NIPPLE
PROVIDE A GAS SHUT OFF VALVE AT WATER HEATER
PROVIDE HIGH & LOW COMBUSTION AIR OPENINGS IN WATER HEATER ENCLOSURE. PROVIDE A ROOF JACK AT ROOF PENETRATION
GAS FLEX CANNOT PENETRATE THE CABINET OF FURNACE ON ROOF
PROVIDE A DRAIN PIPE ON T&P VALVE. CAP OFF GAS PIPE TO DRYER