Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/04/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 02/21/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/10/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 10/28/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL PROVIDE AIR PRESSURE TEST ON ENTIRE SYSTEM 10 LBS MIN 2)SHALL REMOVE UNIONS IN LINE AND REPLACE WITH RIGHT & LEFT HAND NIPPLES. 3)WATER HTR REQUIRES A ENCLOSURE 4)SHALL EXTEND WATER HTR T&P DRAIN AND TERMINATE 6" A.F.F. 5)SHALL PROVIDE DBL WALL FLU VENT FOR WATER HTR THRU ROOF 6)SHALL PROVIDE AGA OR CSA GAS VALVES @ ALLL APPLIANCES 7)CAN NOT HAVE A FLEX CONNECTOR PASS THRU CABINET WALL AND CAN NOT CONNECT 2 FLEXES TOGETHER |
|
| 08/05/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) THIS INSPECTOR URGES THE TENANT TO HIRE A LICENSED PLUMBING CONTRACTOR TO TAKE A LOOK AT THIS WORK: SIZE OF PIPING, LOCATION OF PIPING, APPROVED FITTINGS, VALVES AND APPROVED LOCATIONS |