Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection :13 PSI AIR TEST FROM MOTOR NOW 1" P.S UNDERGROUND TO BLDG 1" UP OVERHEAD TO EXISTING BLD CONNECTION TO STOVE & FURNACE APPROVED EXTEND FURNACE VENT UP 2' ABOVE COOLER WHEN WITHIN 10' OF INTAKE OWNER REMOVED STRUCTURAL OVERHANG FOR UNDERGOUND GAS PIPING |
|
| 07/22/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEE 94 UPC SECTION 121.3 ON GAS PIPING LOCATION 2) WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES AND COUPLINGS SHALL BE USED 3) PROVIDE BONDING OF BLDG GAS PIPING 4) ? VENT FROM FURNACE IS WITHIN 10' OF COOLER INTAKE IT SHALL BE 2' ABOVE TOP OF COOLER 5) RETEST AND CALL BACK IN |