Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*/1)CORRECTIONS MADE OK 2)OK FOR GAS 3)UCC LEFT AT METER. SW GAS 889-1888 | |
| 12/07/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/15 PSI PRESSURE TEST FROM METER SCOTCH COAT UNDER GROUND TO STOVE & WATER HEATER (ONLY) OK. 1)PLEASE READ ALL NOTES LEFT BY INSPECTORS AND COMPLETE ALL WORK, THEN CALL IN FOR INSPECTION | |
| 12/02/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)PROVIDE MINIMUM 10 PSI PRESSURE TEST AT TIME OF INSPECTION AND NO PRESSURE DROP FOR 15 MINUTES. 2)PROVIDE BONDING ON BUILDING GAS PIPING. 3)ALL UNDERGROUND GAS PIPING TO BE 12" MINIMUM COVER. 4)POROVIDE CORRECT SUPPORT FOR WATER HEATER. |