Permit: T04PL01219

Parcel: 126133160


Addresses:

4557 E MONTECITO ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/02/2004 PLUMBING - FINAL Approved IVRS - Inspection :*
07/27/2004 PLUMBING - FINAL Denied IVRS - Inspection :DENIED. (1) INSTALL YOUR BONDING CLAMP ON BLD. GAS PIPING. (2) SEAL PONOTRATIONS INTO BUILDING. (3) WATER HEATER T & P TO TORMINATE 6" TO 24" ABOVE GRADE.
07/22/2004 PLUMBING - FINAL Denied IVRS - Inspection :SHALL PROVIDE 3 SHEET METAL SCREWS PER JOINT @ APPLIANCE COLLAR AND ALL FLU VENT JOINTS
GAS LINE SUPPLY TO WATER HTR & FURNACE REQUIRES A STRAP. SOMEONE COULD STEP ON THIS LINE AND BREAK THE JOINT SEAL
T&P DRAIN APPEARS TO HAVE BACK PITCH
SHALL USE REQUIRED TEST GAGE FOR PRESSURE TEST
07/12/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ALL GAS PIPING ABOVE GRADE SHALL BE MINIMUM 6" ABOVE FINISH GRADE 2) ALL PIPING SHALL BE ARRANGED SO EQUIPMENT CAN BE SERVICED 3) PROVIDE BONDING OF BLDG GAS PIPING 4) WATER HEATER T & P TO GRAVITY DRAIN TO DAYLIGHT