Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04PL01188
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*/ 1) PEX REPIPE ON TWO APARTMENTS OK 2) PRESSURE TEST OK 3) PIPING CONNECTIONS OK 4) OK TO COVER WALLS AND CEILINGS | |
07/09/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) WHILE PEX PIPING MAYBE BUNDLED, CARE MUST BE TAKEN TO INSURE SPERATION BETWEEN HOT AND COLD PIPING TO AVOID TRANSFERENCE OF HEAT 2) ALL HOSE BIBS REQUIRE VACCUM BREAKERS 3) ALL EXTERIOR PENETRATIONS ARE TO BE WEATHER PROOFED 4) INSPECTION STOPPED |