Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/14/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 07/13/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 07/06/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 06/30/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) 10 PSI MIN. TEST SHALL BE ON GAS PIPING AT TIME OF INSPECTION. 2) CALCULATE YOUR BTU DEMAND ON YOUR SYSTEM FOR PROPER PIPE SIZING FOR POOL BTU DEMAND. 3) PROVIDE BOND OF BLD GAS PIPING. 4) WTR HTR T&P RELIEF TO BE FULL SIZE GRAVITY DRAIN TO DAYLIGHT. 5) VENT FROM FURNACE AND WTR HTR WHEN WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE. THIS MAY NOT BE A COMPLETE LIST. |