Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/19/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 07/15/2004 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection :* |
| 07/15/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 06/29/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 14 PSI AIR TEST FROM NEW METER LOCATION, NEW 3/4" OVERHEAD TO WALL HTR, WTR HTR AND STOVE. OK. 1) PROVIDE AGA OR CSA APPROVED GAS VALVES FOR ALL APPLIANCES. 2) PROVIDE BONDING OF BLDG GAS PIPING. 3) WTR HTR T&P RELIEF TO BE RIDGID PIPED, GRAVITY DRAIN TO DAYLIGHT OR PROVIDE SIGNED PETITION OF APPEAL FROM CITY FOR ALTERNATE FORM OF T&P RELIEF WITH PROPER INSTALLATION. |