Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/07/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*/ 1) GAS PRESSURE TEST IS OK 2) GAS SHUT OFF VALVES OK 3) ALL CORRECTIONS HAVE BEEN MADE | |
| 06/29/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 10 PSI TEST IS OK JUST TO FILL TRENCH. PROVIDE ADEQUATE CLEARANCE AROUND VENTS. GAS FLEX CANNOT PENTRATE CABINET OF FURNACE. REMOVE THE UNION FROM CLOSET AND USE REVERSE THREAD COUPLING AND NIPPLE. RETEST SYSTEM. PROVIDE A PETITION OF APPEAL IF USING ALTERNATE METHOD OF T&P DRAIN. INSTALL WTR HTR. EXTEND FURNACE VENT 2' ABOVE AIR INTAKE ON ROOF. |
|
| 06/28/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ NO ONE HOME. I MUST HAVE ACCESS TO ALL GAS APPLIANCES INSIDE DWELLING |