Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/25/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*/ 12 PSI AIR TEST FROM METER ON EXISTING PIPING TO WTR HTR AND FURNACE OK. CORRECTIONS MADE |
| 06/24/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 06/23/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/1) TREAD PROTECTORS AT METER AND FURNACE LOCATION ARE NOT APPROVED COUPLINGS. USE APPROVED COUPLING AT THESE LOCATIONS. 2) WTR HTR T&P TO BE RIDGID PIPED AND GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL FOR ALTERNATE FORM OF T&P ON SITE. 3) PROVIDE BONDING OF BLD GAS PIPING. 4) MAKE CORRECTIONS AND RETEST AND CALL BACK IN FOR INSPECTION. |