Inspection Status: Denied
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 10 PSI AIR TEST SHALL BE ON SYSTEM AT TIME OF INSPECTION. PLEASE READ ALL NOTES FROM 9/22/04 INSPECTION AND COMPLY. WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES AND COUPLINGS SHALL BE USED |
|
| 09/22/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL HAVE A LICENSE PLBS. CONTRACTOR DO WORK ON RENTAL PROPERTY MUST VERIFY CONTRACTOR 2)SHALL EXTEND T&P DRAIN AND TERMINATE 6" ABOVE SLAB 3)SHALL CINNECT NEW GAS LINE AND TEST ENTIRE SYSTEM 4)SHALL SCREW DOWN WATER HTR FLU VENT WITH (3) SHEET METAL SCREWS PER JOINT AND @ APPLIANCE COLLAR 5)SHALL EXTEND GAS LINE INTO WATER HTR ENCLOSURE THEN LOCATE VALVE AND FLEX CONNECTOR |