Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04PL01060

Parcel: 117083730


Addresses:

946 S 7TH AV

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/01/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 10 PSI AIR TEST SHALL BE ON SYSTEM AT TIME OF INSPECTION. PLEASE READ ALL NOTES FROM 9/22/04 INSPECTION AND COMPLY. WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES AND COUPLINGS SHALL BE USED
09/22/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL HAVE A LICENSE PLBS. CONTRACTOR DO WORK ON RENTAL PROPERTY MUST VERIFY CONTRACTOR 2)SHALL EXTEND T&P DRAIN AND TERMINATE 6" ABOVE SLAB 3)SHALL CINNECT NEW GAS LINE AND TEST ENTIRE SYSTEM 4)SHALL SCREW DOWN WATER HTR FLU VENT WITH (3) SHEET METAL SCREWS PER JOINT AND @ APPLIANCE COLLAR 5)SHALL EXTEND GAS LINE INTO WATER HTR ENCLOSURE THEN LOCATE VALVE AND FLEX CONNECTOR