Permit: T04PL01053

Parcel: 116183070


Addresses:

1217 W CONGRESS ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/06/2004 PLUMBING - FINAL Approved IVRS - Inspection :*
07/01/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) THE PERMIT IS FOR A GAS RECONNECT - HOWEVER THER APPEARS TO BE QUITE A BIT OF NEW PIPING. 2) WHERE UNIONS ARE NECESSARY A RIGHT/LEFT NIPPLE AND COUPLING SHALL BE USED. 3) A FLEX CONNECTOR MAY NOT PASS THRU A WALL OR PARTITION. 4) T&P RELIEF DRAIN TO BE FULL SIZE NO THREADED END. 5) NO ACCESS TO INTERIOR. 6) SEAL EXTERIOR WALL PENETRATIONS.