Permit: T04PL01020

Parcel: 110112680

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T04PL01020

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
06/15/2004 PLUMBING - GAS PRESSURE TEST Approved
06/14/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/ 1) 10 PSI TEST ON ENTIRE SYSTEM MINIMUM AT TIME OF INSPECTION SHALL BE IN PLACE WITH NO PRESSURE DROP 2) PROVIDE AGA OR CSA APPROVED GAS VALVE AT ALL APPLIANCE LOCATIONS 3) WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES AND COUPLINGS SHALL BE USED 4) PROVIDE BONDING OF BLDG GAS PIPING 5) WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN TO BE RIDGID FULL SIZE PIPING