Permit: T04PL00906

Parcel: 13811055F

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T04PL00906

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
05/25/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT, T&P VALVE AND DRAIN IS OK. 4) ALL CORRECTIONS HAVE BEEN MADE.
05/21/2004 PLUMBING - GAS PRESSURE TEST Denied 1) GAS PRESSURE TEST GUAGE WAS AT 0 LBS. 10 LBS MIN. REQUIRED. NOTE: WTR HTR ENCLOSURE DOOR WILL REQUIRE FRESH AIR COMBUSTION RELIFE TWO 10X10 LOUVER GRILLS 12" ABOVE FLOOR AND 12" BELOW CEILING. HAVE DOOR THERE AT TIME OF INSP.
05/19/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) MUST REMOVE UNION IN LINE AND REPLACE WITH RIGHT/LEFT HAND NIPPLE. 2) MUST PROVIDE AIR PRESSURE TEST ON ENTIRE SYSTEM FROM METER TO TRAILER CONNECTION.