Permit: T04PL00900


Addresses:

3233 E KLEINDALE RD


Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T04PL00900

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
11/07/2005 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
1) APPROVAL FOR SITE SEWER ONLY
2) HCS CONNECTIONS ON EACH LOT PERMIT
12/21/2004 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*/CONCRETE COVER OF DUCTILE IRON SEWER INSTALLED PER PLAN. PLEASE PROVIDE INFORMATION FROM OTHER INSPECTION FOR FINAL
12/17/2004 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
12/13/2004 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
07/06/2004 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*/ 1) WATER TEST FROM NOW MANHOLE ON 6" SDR 35 WITH 6'-4" HCS CONNECTION STUBS PER APPROVED PLAN FORM APP: 40' NORTH OF NEW MANHOLE ON SITE ONLY. PARTIAL APPROVAL PENDING VERIFICATION OF GRADE APPROVED PLAN ON SITE
07/01/2004 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*/ PLEASE INSTALL PER PLAN. D.I.P. IS CALLED FOR PVC SDR 35 IS INSTALLED.
06/17/2004 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*/ SITE SEWER COVERED WITHOUT INSP. HCS COVERED WITHOUT INSP. PLEASE PROVIDE APPROVAL FROM P.C.W.W.M. ON NEW HCS TO PROPERTY. UNCOVER SITE SEWER FOR INSP. HAVE PLAN ON JOB AT TIME OF INSP.