Permit: T04PL00871

Parcel: 126190240


Addresses:

4332 E MONTECITO ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
05/17/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
05/14/2004 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*/ 13 PSI TEST FROM METER TO STOVE, WTR HTR, FURNACE OK. 1) PROVIDE PROPER BONDING OF BLD GAS PIPING. 2) SECURE ALL PIPING PROPERLY. 3) WTR HTR T&P TO BE RIDGID PIPING GRAVITY DRAIN TO DAYLIGHT. 4) VENTS FROM COMBUSTABLE APPLIANCES WITHIN 10' OF COOLER INTAKE TO BE 2' ABOVE. 5) SEAL ALL PENETRATIONS INTO BLD FROM PIPING.