Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/08/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*/ 20 PSI AIR TEST FROM METER NEW 1" TO HOUSE SERVICE EXISTING CONNECTION THRU TO WHERE WTR HTR AND FURNACE OK. CORRECTION MADE GAS CARD AT METER. 889-1888. |
| 05/18/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
1) PROVIDE PROPER BONDING OF BLD GAS PIPING. 2) USE APPROVED COUPLINGS FOR CONNECTIONS. 3) PROVIDE VALVE PRIOR TO UNION AT BLD SERVICE OR PROVIDE LEFT/RIGHT NIPPLE AND COUPLING. 4) VENT FROM WTR HTR AND FURNACE WHEN WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE TOP OF COOLER WITH APPROVED VENT MATERIAL AND CAP. 5) PROVIDE FUNCTIONAL TEMP AND PRESSURE RELIEF VALVE ON WTR HTR WITH FULL SIZE DRAIN. |