Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/11/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*/ CORRECTIONS HAVE BEEN MADE AS PER LAST REQUEST. APPEAL # 2004-50. CALL GAS CO. 889-1888. CARD AT METER SET |
| 05/11/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
1) VENT FROM FURNACE TO BE PROPERLY SECURED. 2) T&P RELIEF FROM WTR HTR TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL FORM ON SITE WITH INSTALLATION. 3) PROVIDE PROPER BONDING OF BLD GAS PIPING, 12 PSI PRESSURE TEST FROM METER TO STOVE, WTR HTR, FURNACE, DRYER 1" NEW PIPING PARTIAL APPROVAL. |