Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T04PL00776
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/14/2004 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :*/ 1) CONTRACTOR HAS TRIED TO MAINTAIN 12" DEPTH ON PVC - CONTRACTOR IS SCREENING DIRT FOR FILL. OK TO COVER. 2) BEFORE GAS CARD WILL BE RELEASED ALL WTR HTRS MUST MEET MIN. SAFETY STANDARDS, I.E. T&P RELIEF, REMOVABLEDOORS, ACCESSIBLE SHUT OFF VALVE AT COLD WTR INLET ETC. | |
05/12/2004 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | DISCUSSED CODE REQUIREMENTS WITH PLBR AND GENERAL CONTRACTOR. | |
05/11/2004 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PVC YARDWTR PIPING SHALL AT ALL POINTS BE A MIN. OF TWELVE INCHES BELOW GRADE. NOTE - NATIVE SOILS TOO ROCKY FOR BACKFILL. 2) PLBR WOULD DO WELL TO REVIEW ALL OF THE INSP. NOTES. |
|
05/06/2004 | PLUMBING - YARD WTR LINE/TEST | Denied | 1) PLUMBER SHOULD REVIEW APPROVED PLAN TO DETERMINE THE SCOPE AND EXTENT OF HIS WORK 2) ALL WATER HEATER DOORS ARE TO BE REMOVABLE. ALL WATER HEATERS WILL BE INSPECTED FOR SAFETY. ALL WATER HEATERS ARE TO HAVE A VALVE AT THE COLD WATER INLET. 3) HAVE PLUMBER REVIEW INSTALLATION STANDARD #8-315 TRENCHING, COVER AND BACKFILL AS PLASTIC REQUIRES MINIMUM 12" OF COVER, AND NATIVE SOILS ARE INADEQUATE FOR BACKFILL | |
05/05/2004 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :*/ TO AVOID RE-INSPECTION FEES, SEE 103.5.4.2 - 94 UPC. |