Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T04PL00743
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/04/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection : See detailed listing on site.| 999*/ 1) GAS PRESSURE TEST IS OK 2) GAS SHUT OFF VALVES OK 3) WATER HEATER FLU VENT, T & P VALVE AND DRAIN IS OK |
|
| 04/22/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 14 PSI TEST 2) REMOVE THE THREADS FROM END OF T & P RELIEF DRAIN LINE 3) WATER HEATER VENT IS INSTALLED UPSIDE DOWN 4) PROVIDE A GAS SHUT OFF VALVE AT UNION WHERE GAS PIPE CONNECTS TO THE HOUSE LINE 5) SECURE THE GAS LINE TO THE WATER HEATER. RETEST SYSTEM AFTER INSTALLING GAS SHUT OFF VALVE. ALSO PROVIDE AN APPROVED CAP ON DOUBLE WALL VENT FOR WATER HEATER. THE CAP YOU HAVE IS NOT MADE FOR DOUBLE WALL PIPE. RECALL FOR INSPECTION |