Permit: T04PL00743

Parcel: 129120330


Addresses:

1620 S FREMONT AV


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T04PL00743

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
05/04/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GAS PRESSURE TEST IS OK 2) GAS SHUT OFF VALVES OK 3) WATER HEATER FLU VENT, T & P VALVE AND DRAIN IS OK
04/22/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 14 PSI TEST 2) REMOVE THE THREADS FROM END OF T & P RELIEF DRAIN LINE 3) WATER HEATER VENT IS INSTALLED UPSIDE DOWN 4) PROVIDE A GAS SHUT OFF VALVE AT UNION WHERE GAS PIPE CONNECTS TO THE HOUSE LINE 5) SECURE THE GAS LINE TO THE WATER HEATER. RETEST SYSTEM AFTER INSTALLING GAS SHUT OFF VALVE. ALSO PROVIDE AN APPROVED CAP ON DOUBLE WALL VENT FOR WATER HEATER. THE CAP YOU HAVE IS NOT MADE FOR DOUBLE WALL PIPE. RECALL FOR INSPECTION