Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/21/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ CORRECTION MADE GAS CARD AT METER. 889-1888. |
| 04/20/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 12 PSI PRESSURE TEST FROM WTR HTR NEW 3/4" SCOTCH COAT UNDERGROUND TO HOUSE SERVICE ENTRANCE EXISTING TO WTR HTR, STOVE, FURNACE. 1) PROVIDE PROPER BONDING OF BLD GAS PIPING. 2) VENT FROM WTR HTR WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE TOP OF COOLER. 3) HAVE AGA OR CSA APPROVED GAS VALVES FOR ALL APPLIANCES. 4) INSTALL UPPER COMBUSTION AIR AT WTR HTR. |