Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/16/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT OK. 4) NOTE: PLBG CONTRACTOR WILL LOWER EXISTING T&P DRAIN SO THAT NO TRAPPED WTR WILL REMAIN IN LINE. 5) GAS PACK ON ROOF IS OK. |
| 04/15/2004 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ PLEASE CALL FOR AN INSP WHEN SOMEONE WILL BE HOME. PROVIDE A MIN. 10 LB PRESSURE TEST ON SYSTEM. |