Permit: T04PL00668

Parcel: 131111600


Addresses:

5726 E CALLE AURORA

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
06/11/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*/ 1) 15 PSI AIR TEST FROM METER NOW 3/4" ABOVE GROUND TO WATER HEATER, DRYER, STOVE (ONLY) OK. CORRECTION MADE. GAS CARD AT METER
06/07/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/ SYSTEM SHALL HOLD PREESURE.
06/04/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/ 10 PSI TEST MUST HOLD TIGHT FOR MINIMUM 15 MINUTES. 1) PROVIDE GALV. NIPPLE AT OLD WTR HTR LOCATION ON H20 PIPING. 2) APPROVED VENT CAP FOR WTR HTR TO BE INSTALLED ON VENT.
04/30/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
04/28/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/ 1) PROVIDE GAS VALVE FOR WATER HEATER IN ACCESSIBLE LOCATION 2) SECURE ALL GAS PIPING PROPERLY 3) PROVIDE T & P DRAIN WITH APPROVED DRAINAGE MATERIAL
04/14/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*/ 1) 10 PSI PRESSURE TEST ENTIRE SYSTEM AT TIME OF INSP. 2) AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES. 3) WTR HTR TO BE INSTALLED WITH CORRCT VENTING AND T&P TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL FOR ALTERNATE FORM OF T&P RELIEF ON SITE WITH PROPER INSTALLATION. 4) PROVIDE PROPER BONDING OF BLD GAS PIPING. 5) SECURE ALL PIPING WITH APPROVED CLAMPS.