Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
Permit Number - T04PL00636
Inspection Description - PLUMBING - GAS PRESS TEST FNL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/09/2004 | PLUMBING - GAS PRESS TEST FNL | Approved | IVRS - Inspection 0000* | |
| 04/08/2004 | PLUMBING - GAS PRESS TEST FNL | Denied | IVRS - Inspection 0999* ACTUAL ADDRESS 2820 ON HOUSE. A) GAS LINE IN SHED FOR WATER HEATER TO BE SUPPORTED 6" OFF GROUND. b) W.H. EXHAUST REQUIRES 3" CLEAR TO COMBUSTIBLES. c) TPRU @ WATER HEATER ISN'T PRPERLY TERMINATED. d) SHUT OFF VALVE REQUIRED UPSTREAM OF UNION @ ENTRANCE TO KITCHEN. 2) THERE ARE OTHER PLUMB VIOLATIONS NOT CONNECTED TO GAS INSP THAT SHOULD BE CORRECTED. |