Permit: T04PL00623

Parcel: 129054270


Addresses:

2207 E 19TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
08/17/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
06/11/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/ 1) ALL APPLIANCES TO HAVE AGA OR CSA APPROVED GAS VALVES 2) STOVE GAS PIPING SHALL BE RIDGID PENETRATION THRU WALL OF CABINET 3) PROVIDE BONDING OF BLDG GAS PIPING 4) UNION IN LINE PIPING SHALL BE REPLACED WITH LEFT-RIGHT NIPPLE AND COUPLING 5) VENT FROM WATER HEATER WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE TOP OF COOLER 6) WATER HEATER TEMPERATURE AND PRESSURE RELIEF PIPING TO BE FULL SIZE RIDGID PIPE, GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL (SIGNED) FROM CITY WITH CORRECT INSTALLATION 7) PLEASE PROVIDE WORKING 0-15 PSI GAUGE FOR PRESSURE TEST 8) THIS MAY NOT BE A COMPLETE LIST