Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04PL00598

Parcel: 129064230


Addresses:

2328 E 21ST ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/22/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/ 1) ALL CORRECTIONS MADE OK. 2) OK FOR GAS. 3) UCC LEFT AT METER. 4) OK TO COVER. 5) SW. GAS 889-1888
04/21/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 11 PSI PRESSURE TEST FROM METER 1" TO EXISTING GAS PIPING UNDERGROUND OK. 1) HARD PIPE GAS THRU WEATHER PROOF ENCLOSURE OF WTR HTR. 2) ALL APPLIANCES TO HAVE AGA OR CSA APPROVED GAS VALVES. 3) VENT FROM FURNACE TO EXTEND 3' COOLER WHEN WITHIN 10' OF INTAKE AND TERMINATE WITH APPROVED CAP. 4) PROVIDE BONDING OF BLD GAS PIPING
04/16/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ NO TEST
04/14/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ NOT READY - NO TEST ON SYSTEM.