Date Description Inspector Results Comments
04/21/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ CORRECTION MADE.
04/06/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 14 PSI AIR TEST FROM METER NEW 3/4" PIPING TO WTR HTR AND FURNACE APPROVED. 1) SECURE ALL GAS PIPING PROPERLY - 2 HOLE STRAPS. 2) PROVIDE PROPER BONDING OF GAS PIPING - 2 BONDING CLAMPS AND #4 OR #6 COPPER WIRE FROM BLD GAS PIPE TO COLDWTR PIPING. GAS CARD AT METER 889-1888.