Permit: T04PL00542

Parcel: 131131600

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/25/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ CORRECTIONS MADE GAS CARD AT METER. PETITION OF APPEAL ON SITE #2004-38
03/24/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) 20 PSI PRESSURE TEST FROM METER NEW 1" P.E. LINE UNDERGROUND TO STUB UP AT HOUSE, NEW 1" OVER HEAD STEEL TO WATER HEATER FURNACE. SEE NOTE #2 FROM 3/23/04 INSPECTION 3) SEE NOTE #4 FROM 3/23/04 INSPECTION (BONDING NOT GROUNDING) 4) RIDGID PIPING AT FURNACE
03/23/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) HAVE WTR HTR ADDED TO PERMIT. 2) PROVIDE PETITION OF APPEAL FOR ALTERNATE FORM OF T&P RELIEF ON SITE AT TIME OF NEXT INSP. 3) CONNECT ENTIRE SYSTEM TOGETHER AND PRESSURE TEST. IF UNION IS USED IT SHALL BE PRECEDED BY AN APPROVED GAS VALVE. 4) PROVIDE PROPER BONDING OF BLD GAS PIPING. 5) HAVE APPROVED GAS VALVES AT ALL APPLIANCES.