Permit: T04PL00538

Parcel: 136335700


Addresses:

9131 E CREEK ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/25/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 12 PSI AIR TEST FROM METER 3/4 PIPING TO WTR HTR, DRYER AND FURNACE APPROVED. CORRECTIONS MADE. GAS CARD AT METER.
03/23/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) GAS SYSTEM TO HAVE MIN. 10 PSI AT TIME OF INSPECTION. 2) PENETRATIONS THRU ROOF TO HAVE APPROVED FLASHINGS, DO NOT CUT THEM. 3) PIPING ON ROOF TO BE SUPPORTED AND SECURED EVERY 8'. 4) NO UNION SHALL BE USED IN LINE PIPING. WHERE UNIONS ARE NECESSARY USE RIGHT/LEFT NIPPLE AND COUPLINGS. 5) VENT FROM FURNACE WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE COLLER. 6) PROVIDE PROPER BONDING ON GAS PIPING. 7) PROVIDE APPROVED AGA OR CSA GAS VALVES AT ALL APPLIANCES.