Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 04/13/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection 0000*/ CALL BACK ABOVE GRADE. OK TO COVER SITE WORK. TEST OK. COMPLETE C.O. TO GRADE FILL SEPTIC TANK COMPLETE VENT K-SINK. |
| 04/12/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NOT READY FOR INSP. 2) REQUIRE WTR TEST ON SEWER. 3) WIPING OF LEAKING FITTINGS NOT ACCEPTED METHOD OF REPAIRING LEAKS. CUT OUT FITTINGS AND REPLACE WITH NEW. 4) ABS IS NOT APPROVED IN EXPOSED EXTERIOR LOCATION. 2" VENT DOES NOT TERMINATE ABOVE ROOF. 5) SEPTIC TANK TO BE BROKEN AND INSP. BEFORE BACKFILLING. |
| 04/07/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*/ NEW HCS AND TAP TO PROPERTY LINE ONLY - APPROX 35' ABS INSTALLED. OK TO COVER. |
| 04/06/2004 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ PLEASE CALL AGAIN. |