Permit: T04PL00374

Parcel: 120032110


Addresses:

1031 W EBNER PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/21/2004 PLUMBING - FINAL Approved IVRS - Inspection :*
05/18/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
04/19/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 10 PSI MIN. FOR 15 MIN. ON ENTIRE SYSTEM. PROVIDE PROPER BONDING OF BLD GAS SYSTEM. 3) USE APPROVED FITTINGS AT ALL PIPE CONNECTION LOCATIONS. 4) WHERE UNIONS ARE REQUIRED LEFT/RIGHT NIPPLES AND COUPLINGS SHALL BE USED. 5) PROVIDE 12" MIN. COVER FOR ALL UNDERGROUND PIPING. 6) PRIME AND TAPE ALL UNCOATED PIPING AND FITTING. 7) RISER AT METER SHALL BE SCOTCH COATED UNDERGROUND AND FITTING TO BE PRIMED AND TAPED.
03/03/2004 PLUMBING - FINAL Denied 1) MUST PROVIDE AIR PRESSURE TEST ON SYSTEM 10 LBS MIN. 2) MUST REMOVE UNION IN LINE UNDERGROUND AND TAPE PRIMER AND 10 MIL TAPE ALL JOINTS UNDERGROUND. 3) MUST SCREW DOWN WTR HTR FLU VENT TO VENT CONNECTOR WITH THREE SHEET METAL SCREWS PER JOINT. 4) MUST EXTEND T&P DRAIN AND TERMINATE 6" ABOVE FLOOR. 5) MUST CHANGE SHUT OFF VALVE FOR KITCHEN RANGE TO AN AGA OR CSA VALVE.