Date Description Inspector Results Comments
05/21/2004 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
04/19/2004 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection IVRS - Inspection 0000*
03/15/2004 PLUMBING - GAS PRESS TEST FNL Denied 1) NO TEST ON SYSTEM 2) MUST PAY RE-INSPECTION FEE BEFORE NEXT INSPECTION
03/10/2004 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection 0999*/ 1) MUST HOLD 10# FOR 15 MINUTES MIN. 2) ALL OTHER CORRECTIONS MADE OK. 3) ALMOST 2 POUND DROP IN FIVE MINUTES.
03/03/2004 PLUMBING - GAS PRESS TEST FNL Denied