Permit: T04PL00360

Parcel: 11205283F


Addresses:

2902 N CAMPBELL AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04PL00360

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/26/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/ FINAL OK. TESTING ON BACKFLOW DEVICES OK. INFOR ON FILE.
04/12/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE PROVIDE APPROVED DRAWING ON JOB AT TIME OF INSP. 2) PLEASE PROVIDE LISTING ON FOOT SPA. THAT IT HAS BEEN TESTED UNDER ACTUAL BACKFLOW CONDITIONS WITH VACUUM OF 0-25 INCHES OF MERCURY - I WILL NEDD THIS ON SITE AT TIME OF NEXT INSP OR INSTALL PROPER BACKFLOW DEVICES. 3) PLEASE PROVIDE APPROVED REVISED PLAN ON JOB.
03/17/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ PLEASE PROVIDE PROPER BACKFLOW PROTECTION AT FOOT SPAS BOTH HOT AND COLD WTR. FOOT SPA HAS NO AIR CAP AT FILL SEE SEC. 413.2 AND 413.3, 804.0. ALSO NEED APPROVED INDIRECT WASTE RECEPTORS TO RECEIVE THE DISCHARGE, 805.0. PRESSURE DRAINAGE CONNECTIONS