Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/24/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/23/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 10 PSI PRESSURE TEST FROM METER NEW 1" UP TO HOUSE TO 3/4" TO WTR HTR AND DRYER AND 3/4" TO FURNACE ONLY APPROVED. GAS CARD AT METER SW. GAS 889-1888. VENT FROM FURNACE TO EXTEND 3' ABOVE COOLER INTAKE. |
| 03/22/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PROVIDE LEFT AND RIGHT NIPPLE AND COUPLING WIHERE UNIONS ARE BEING USED 2) PROVIDE BONDING OF GAS PIPING |