Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04PL00332

Parcel: 138170060


Addresses:

324 E ELVIRA RD #E


Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Permit Number - T04PL00332

Inspection Description - PLUMBING - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
12/15/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL REMOVE FLEX LINE IN T&P DRAIN 2)SHALL LOCATE SINGLE WALL FLU VENT MIN 6" OF COMBUSTIONABLE MATERIAL 3)SHALL TERMINATE T&P DRAIN MIN 1" ABOVE DRIP PAN 4)PROVIDE (3) SHEET METAL SCREWS PER JOINT @ APPLIANCE COLLAR FOR WATER HTR FLU VENT
07/06/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) MUST PROVIDE A VARIANCE FORM FOR ALTERNATE METHOD OF INSTALLATION OF WATER HEATER T & P DRAIN AND HAVE THIS FORM ON SITE AT TIME OF INSPECTION SEE INSTRUCTION SHEET LEFT BY INSPECTOR 2) MUST PROVIDE (3) SHEET METAL SCREWS PER JOINT ON WATER HEATER FLUE VENT AND AT APPLIANCE COLLAR