Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
Permit Number - T04PL00332
Inspection Description - PLUMBING - FINAL
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL REMOVE FLEX LINE IN T&P DRAIN 2)SHALL LOCATE SINGLE WALL FLU VENT MIN 6" OF COMBUSTIONABLE MATERIAL 3)SHALL TERMINATE T&P DRAIN MIN 1" ABOVE DRIP PAN 4)PROVIDE (3) SHEET METAL SCREWS PER JOINT @ APPLIANCE COLLAR FOR WATER HTR FLU VENT |
|
| 07/06/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) MUST PROVIDE A VARIANCE FORM FOR ALTERNATE METHOD OF INSTALLATION OF WATER HEATER T & P DRAIN AND HAVE THIS FORM ON SITE AT TIME OF INSPECTION SEE INSTRUCTION SHEET LEFT BY INSPECTOR 2) MUST PROVIDE (3) SHEET METAL SCREWS PER JOINT ON WATER HEATER FLUE VENT AND AT APPLIANCE COLLAR |